G-1994 Isolation RelayDataSheet: G-1994ii.pdf 06-08-01 125KB
The G-1994 is a single input contact multiplier and isolation device for applications where two or three isolated outputs are needed to mirror the KYZ input. The G-1994 can be powered with either AC or DC external voltage source. Optional fuses for the input and outputs may be provided. A lexan safety cover is standard. |
|
G-9794 Dual Contact RelayDataSheet: G-9794.pdf 06-08-02 215KB
The G-9794 is a dual input contact multiplier and isolation device for applications where kWh and kVARh pulses need to be monitored by two parties, i.e. the transmission company and the distribution entity. AC powered, this unit features mercury-wetted relays for bounce-free metering from either a KYZ or Form-A contact source. Two outputs per input are provided, with the option of using the unit as a single input, four output device. A safety cover is provided. The unit can also be housed in a NEMA 3R enclosure at an additional cost. |
|
G-9894 Solid State Isolation RelayDataSheet: G-9894ii.pdf 06-18-01 56KB
The G-9894 provides three KYZ outputs from a single set of KYZ inputs. Like the G-1994, this unit offers either AC or DC operation. This device uses solid state outputs to perform bounce-free keying. A safety cover is provided. |
|
G-9694 Solid-State AC Isolation RelayDataSheet: G-9694.pdf 10-08-03 27KB
As environmental concern about mercury filled relays grows, the Solid-State G-9694 will find application. This unit uses triac outputs to perform the bounce-free keying that the metering industry requires. Like the G-9794, it is an AC powered dual input unit requiring either a KYZ or Form-A contact source, with two outputs per input. This unit can also be configured to offer four outputs for a single input. A safety cover is provided. The unit can be housed in a NEMA 3R enclosure at an additional cost. |
|
G-9694B Solid-State AC Isolation RelayDataSheet: G-9694B.pdf 8-25-08 27KB
The Solid-State G-9694B provides an on board AC to DC power supply to yield the wetting voltage to the KYZ input contacts and the onboard electronic circuitry. This unit uses OPTO-Mos solid state relays for it's output contacts which provide bounce free keying that the metering industry requires. This is a dual input device requiring either a KYZ or Form A contact closure, with two outputs per input. The unit may also be configured to offer four outputs for a single input. The output solid state relays are non-polarity sensitive. |
|
G-8202-N Kwh TotalizerDataSheet: G-8202N.pdf 10-08-03 21KB
For power company applications where several channels of K Y Z metering pulses need to be combined and totalized on to one K Y Z line for counting or recording. The G-8202-N uses a simple sequential logic to combine the input pulses from two, three or four different KWH meter circuits. The inputs have switch selectable scaling (divide 1,2,4,8,16) as does the output. The four inputs may all be added or the third and fourth input may be subtracted from the outputs. Switch selection allows the following output rate choices: 380, 190, 95, 47.5, or 23 PPM. The inut pulses may be simultaneous, overlap or at any time period apart. |
|